Discussion:
[rancid] Patch to srancid for improved handling of Dell PowerConnect M-Series switches
Frank Fegert
2015-10-01 20:58:05 UTC
Permalink
Hello all,

i'd like to propose the attached patch to srancid for an improved hand-
ling of Dell PowerConnect M-Series switch devices. The patched version
was successfully tested against the Dell PowerConnect M6348 and M8024-k
models.
Besides some general output beautification -- additional section headers
and newlines -- it basically deals with the system uptime data in the
"show version" output. It also filters the temperature values from the
sensors in the "show system" output. For output samples of both commands
see below.
Can you please consider the provided patch for inclusion in the next
rancid release?

Thanks & best regards,

Frank Fegert



## "show version" sample ##############################################
switch1# show version

System Description................ Dell Ethernet Switch
System Up Time.................... 90 days, 04h:48m:41s
System Contact.................... <contact email>
System Name....................... <system name>
System Location................... <location>
Burned In MAC Address............. F8B1.566E.4AFB
System Object ID.................. 1.3.6.1.4.1.674.10895.3041
System Model ID................... PCM8024-k
Machine Type...................... PowerConnect M8024-k

unit image1 image2 current-active next-active
---- ----------- ----------- -------------- --------------
1 5.1.3.7 5.1.8.2 image2 image2
2 5.1.3.7 5.1.8.2 image2 image2

## "show system" sample ###############################################
switch1# show system

System Description: Dell Ethernet Switch
System Up Time: 90 days, 04h:48m:19s
System Contact: <contact email>
System Name: <system name>
System Location: <location>
Burned In MAC Address: F8B1.566E.4AFB
System Object ID: 1.3.6.1.4.1.674.10895.3041
System Model ID: PCM8024-k
Machine Type: PowerConnect M8024-k
Temperature Sensors:

Unit Description Temperature Status
(Celsius)
---- ----------- ----------- ------
1 System 39 Good
2 System 39 Good

Power Supplies:

Unit Description Status

---- ----------- -----------
NA NA NA
NA NA NA