Discussion:
[rancid] output that triggers annoying email notification - I am sure we have all seen this before from rancid. :)
Brian Lam
2010-06-21 19:32:26 UTC
Permalink
All,

I am using rancid 2.3.2. with force 10 switches (S50N - 48-port).

The following line keeps triggering an email notification, which is annoying
because we get desensitized to the notification email when there is an
actual change.

- !Chassis: 0 up medium up up up up up
up
+ !Chassis: 0 up low up up up up up
up

The router command that spit out this status is (I believe) 'show system'.
I searched for the command and believe it's in the following file:

bin/f10rancid: {'show system' => 'ShowChassis'},

I am going to hack the script to see if I can filter the annoying output. I
will probably will remove the command 'show system' if I don't figure out
how to filter out the annoying line. But this affect the output globally
and I would like to get the rest of the output.

I was wondering if someone has experience changing the code base to deal w/
this case? Any pointer would be apreciated. Thanks!

Example of system command and system outputs:

r305-sw2-secondary#show system

Stack MAC : 00:01:e8:d6:86:6e

-- Unit 0 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S50N - 48-port E/FE/GE (SB)
Current Type : S50N - 48-port E/FE/GE (SB)
Master priority : 0
Hardware Rev : 2.0
Num Ports : 52
Up Time : 11 wk, 5 day, 11 hr, 47 min
FTOS Version : 7.8.1.3
Jumbo Capable : yes
POE Capable : no
Burned In MAC : 00:01:e8:d6:86:6e
No Of MACs : 3

-- Module 0 --
Status : not present

-- Module 1 --
Status : not present

-- Power Supplies --
Unit Bay Status Type
---------------------------------------------------------------------------
0 0 up AC
0 1 absent

-- Fan Status --
Unit TrayStatus Speed Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
--------------------------------------------------------------------------------
0 up low up up up up up up

-- Unit 1 --
Unit Type : Member Unit
...
...


Brian Lam | IT/Operations | Rockyou, Inc.
Brian Lam
2010-06-22 17:44:00 UTC
Permalink
I haven't heard back so I went ahead and comment out the line below:

{'show system' => 'ShowChassis'},

Unfortunately, it removed a lot of valuable information so I am going to
attempt to 'intercept' the output files and remove the '!Chassis...' line
there in the file:

- !Chassis: 0 up medium up up up up up
up
+ !Chassis: 0 up low up up up up up
up

I think I narrow down it to the following in the bin/f10rancid:

...
...
...
open(OUTPUT,">$host.new") || die "Can't open $host.new for writing: $!\n";
select(OUTPUT);
# make OUTPUT unbuffered if debugging
if ($debug) { $| = 1; }

if ($file) {
print STDERR "opening file $host\n" if ($debug);
print STDOUT "opening file $host\n" if ($log);
open(INPUT,"<$host") || die "open failed for $host: $!\n";
} else {
print STDERR "executing clogin -t $timeo -c\"$cisco_cmds\" $host\n" if
($debug);
print STDOUT "executing clogin -t $timeo -c\"$cisco_cmds\" $host\n" if
($log);
if (defined($ENV{NOPIPE})) {
system "clogin -t $timeo -c \"$cisco_cmds\" $host </dev/null > $host.raw
2>&1" || die "clogin failed for $host: $!\n";
open(INPUT, "< $host.raw") || die "clogin failed for $host: $!\n";
} else {
open(INPUT,"clogin -t $timeo -c \"$cisco_cmds\" $host </dev/null |") ||
die "clogin failed for $host: $!\n";
}
}
...
...
...

Do let me know if I am completely off base here.

Brian Lam | IT/Operations | Rockyou, Inc.
Post by Brian Lam
All,
I am using rancid 2.3.2. with force 10 switches (S50N - 48-port).
The following line keeps triggering an email notification, which is
annoying because we get desensitized to the notification email when there is
an actual change.
- !Chassis: 0 up medium up up up up up
up
+ !Chassis: 0 up low up up up up up
up
The router command that spit out this status is (I believe) 'show system'.
bin/f10rancid: {'show system' => 'ShowChassis'},
I am going to hack the script to see if I can filter the annoying output.
I will probably will remove the command 'show system' if I don't figure out
how to filter out the annoying line. But this affect the output globally
and I would like to get the rest of the output.
I was wondering if someone has experience changing the code base to deal w/
this case? Any pointer would be apreciated. Thanks!
r305-sw2-secondary#show system
Stack MAC : 00:01:e8:d6:86:6e
-- Unit 0 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S50N - 48-port E/FE/GE (SB)
Current Type : S50N - 48-port E/FE/GE (SB)
Master priority : 0
Hardware Rev : 2.0
Num Ports : 52
Up Time : 11 wk, 5 day, 11 hr, 47 min
FTOS Version : 7.8.1.3
Jumbo Capable : yes
POE Capable : no
Burned In MAC : 00:01:e8:d6:86:6e
No Of MACs : 3
-- Module 0 --
Status : not present
-- Module 1 --
Status : not present
-- Power Supplies --
Unit Bay Status Type
---------------------------------------------------------------------------
0 0 up AC
0 1 absent
-- Fan Status --
Unit TrayStatus Speed Fan0 Fan1 Fan2 Fan3 Fan4 Fan5
--------------------------------------------------------------------------------
0 up low up up up up up up
-- Unit 1 --
Unit Type : Member Unit
...
...
Brian Lam | IT/Operations | Rockyou, Inc.